IMPORTANT NOTE - LUMINAIRES STANDARD EN IEC 60598-1:2021 WILL BE IMPLEMENTED ON 2021-09-19!
Publisher:Admin  Source:  Date:2021/9/22

1. NEW STANDARDS INTRODUCTION

• EN IEC 60598-1:2021 luminaries - Part 1: General requirements and tests,will be published on 2021-09-19.

• The existing certificate according to EN 60598-1:2015+A1:2018, which will expire after 2024-03-19. The CE-LVD certificate of all Luminaires shall be updated to the latest version before 2024-03-19.

1.jpg


2. SIGNIFICANT TECHNICAL CHANGES

a) Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source;

b) Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0;

c) Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984;

d) Addition of Subclause 3.3.25, UV protection of cable;

e) Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493);

f) Revision of the requirements for functional earth and protective earth;

g) Addition of Clause 4.35, Protection against fast rotating parts;

h) Revision of Clause 3.2, Rated voltage marking;

i) Revision of Subclause 5.2.10, Cord anchorage;

j) Revision of Annex G for touch current and protective conductor current test set-up;

k) Addition of requirements for constant light output function and programmable current output;

l) Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage;

m) Introduction of PELV;

n) Introduction of Ethernet power supply connection for luminaires (PoE);

o) Section 9, Introduction of IPX9;

p) Addition of Subclause 3.3.26 for wall mounted luminaires;

q) Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C;

r) Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits;

s) Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/AMD2:2019;

t) Revision of Subclause 10.2.2, alternative DC electric strength test;

u) Revision of Annex D for recessed luminaires;

v) Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands;

w) Revision of use of bridging capacitors in luminaires;

x) Revision of electrical connection to class III plugs.


3. EXAMPLES OF OUR TEST CAPABILITIES

• IEC/EN/AS/NZS 60598 series;

• IEC/EN/AS/NZS 61347 series;

• IEC/EN/AS/NZS 60968;

• IEC/EN/AS/NZS 62560;

• IEC/EN 61195;IEC/EN 61199;

• IEC 62471;IEC/TR 62778;IEC 62031;

• UL 1598;UL1993;UL 153;UL 8750;UL 1310。

 

 2.jpg

 

 BACL Service:

BACL can provide you efficient and reliable global market certification services, such as IECEE CB Scheme NCB and CBTL, United States(NRTL, FCC, ENERGY STAR), Canada(ISED, SCC), EU(CE), United Kingdom (UKCA AB & AOC), Northern Ireland(UKNI), Korea(KC), Japan(MIC), Singapore(IMDA), Hong Kong(OFCA), Taiwan (NCC, BSMI), Egypt (NTRA, GOEIC), South Africa(SABS), Vietnam (MIC), Saudi Arabia (SASO, CITC), Philippines (NTC), Thailand (NBTC), Malaysia (SIRIM), India(BIS, WPC, TEC)and other services to assure your products still smoothly entering into the international trade market even when the international trade barriers are becoming increasingly fierce.